Product Information Take a Closer Look

SF Series
Hazardous Areas

Features

  • NEMA 4X environmental rating
  • SlimView Front-Access (SF) Design
  • Industrial Flat Panel display
  • 15", 17" or 20" Active matrix color TFT
  • 250 Nit brightness, 172 Nit viewable through protective screen
  • 15" – 1024 x 768 resolution
  • 17" – 1280 x 1024 resolution
  • 20" - 1600 x 1200 resolution
  • Auto-Syncs to lower resolutions
    • On-screen set-up menu/controls
    • Protective safety glass over display
    • Standard video interface
  • Provided with Integrated Industrial Computer
       OR
  • With Signal Extender for remote PC interface
    • Signal Extender mounted inside rear panel
    • Copper Extender - Remote PC up to 400' for 15" and 17" displays, 200' for 20" displays
    • Fiber Extender – Remote PC up to 3000'
  • Optional industrial touchscreen
  • Integrated industrial membrane keyboard with pointing device - touchmouse or trackball
  • Serial touchscreen controller/drivers
  • Sloped top design for water run-off
  • Curved keyboard front design
  • Front access door with compression latches
    • Internal, hidden hinges – Designed for easy lift-off of front door
  • Two Internal blowers provided for continuous air circulation/cooling
  • Conduit plates for power/communication connections
  • Suitable for direct wall, table top or pedestal mounting
  • Internal, multi-outlet surge suppressor wired to terminal strip
  • Operating Temperature
    • NEMA 4X with display/extender: 0-40°C
    • NEMA 4X with display/computer: 0-30°C
  • Shipped fully assembled
  • Two year warranty

Purge Features

Model # SV-XP (Class I, Division 1, Groups B, C & D)

  • Integrated Type X Purge System
  • Provides positive pressurization
  • Internal pressure switch
  • External spark arresting vent with flowswitch
  • Automatic rapid air exchange
  • 5 Minute quick start-up
  • Automatic power shut-down upon pressure loss
  • Provisions for remote alarming
  • External bulkhead air connection
  • Uses inert gas/compressed air
  • Minimal air usage - only 7 SCFH
  • Power entry via junction box
  • UL/cUL Listed - Class I, Division 1,
    Groups B, C, D
  • For use with SF, SFD, and SO versions

Model # SV-ZP (Class I, Division 2, Groups A, B, C & D)
Check to see if the new Non-Purged Option is suitable for your configuration.

  • Integrated Type Z Purge System
  • Provides positive pressurization
  • Internal pressure switch
  • External spark arresting vent
  • Manual rapid air exchange
  • 5 Minute quick start-up
  • Manual power shut-down upon pressure loss
  • Provisions for remote alarming
  • External bulkhead air connection
  • Uses inert gas/compressed air
  • Minimal air usage - only 7 SCFH
  • Power entry via junction box
  • UL/cUL Listed - Class I, Division 2, Groups A, B, C, D
  • For use with SO, ST and SF versions

Configuration Guides

Outline Drawings

Specifications